Микросхема для контроля мощности и энергии в активной и земляной шинах источников питания с напряжениями от 0 В до 100 В

Документы:

На английском языке: Datasheet Linear Technology LTC2946CMS#PBF

    ПоставщикПроизводительНаименованиеЦена
    ЭлитанLinear TechnologyLTC2946CMS-1#PBF475 руб.
    Подробнее об условиях поставки »

Варианты написания: LTC2946CMSPBF, LTC2946CMS PBF

Выписка из документа:
LTC2946 Wide Range I2C Power, Charge and Energy Monitor FEATURES DESCRIPTION
The LTC®2946 is a rail-to-rail system monitor that measures current, voltage, power, charge and energy. It features an operating range of 2.7V to 100V and includes a shunt regulator for supplies above 100V. The current measurement common mode range of 0V to 100V is independent of the input supply. A 12-bit ADC measures load current, input voltage and an auxiliary external voltage. Load current and internally calculated power are integrated over an external clock or crystal or internal oscillator time base for charge and energy. An accurate time base allows the LTC2946 to provide measurement accuracy of better than ±0.6% for charge and ±1% for power and energy. Minimum and maximum values are stored and an overrange alert with programmable thresholds minimizes the need for software polling. Data is reported via a standard I2C interface. The LTC2946 I2C interface includes separate data input and output pins for use with standard or opto-isolated I2C connections. The LTC2946-1 has an inverted data output for use with inverting opto-isolator configurations.
L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks and Hot Swap is a trademark of Linear Technology Corporation. All other trademarks are the property of their respective owners. n Rail-to-Rail Input Range: 0V to 100V Wide Input Supply Range: 2.7V to 100V Shunt Regulator for Supplies >100V ADC with Less Than ±0.4% Total Unadjusted Error 12-Bit Resolution for Current and Voltages ±1% Accurate Power and Energy Measurements ±0.6% Accurate Current and Charge Measurements Additional ADC Input Monitors an External Voltage Internal ±5% or External Time Bases Continuous Scan and Snapshot Modes Stores Minimum and Maximum Values Alerts When Limits Exceeded Split SDA Pin Eases Opto-Isolation Shutdown Mode wit...

Рекомендуемые материалы по теме:

При перепечатке материалов с сайта прямая ссылка на РадиоЛоцман обязательна.

Срезы ↓
радиолоцман вконтакте радиолоцман одноклассники радиолоцман facebook радиолоцман twitter радиолоцман google плюс