Смарт-ЭК - поставщик алюминиевых корпусов LinTai

Datasheet LTC2301, LTC2305 (Analog Devices) - 5

ПроизводительAnalog Devices
Описание2-Channel, 12-Bit ADCs with I2C Compatible Interface
Страниц / Страница26 / 5 — POWER REQUIREMENTS. The. denotes the specifi cations which apply over the …
Формат / Размер файлаPDF / 907 Кб
Язык документаанглийский

POWER REQUIREMENTS. The. denotes the specifi cations which apply over the full operating temperature

POWER REQUIREMENTS The denotes the specifi cations which apply over the full operating temperature

25 предложений от 17 поставщиков
1-Channel Single ADC SAR 14ksps 12-bit Serial Automotive 12-Pin MSOP Tube
EIS Components
Весь мир
LTC2301HMS#PBF
Analog Devices
222 ₽
Maybo
Весь мир
LTC2301HMS#PBF
Analog Devices
720 ₽
Элитан
Россия
LTC2301HMS
Analog Devices
873 ₽
LTC2301HMS#TRPBF
Linear Technology
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

LTC2301/LTC2305
POWER REQUIREMENTS The
l
denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. (Note 4) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
VDD Supply Voltage l 4.75 5 5.25 V IDD Supply Current 14ksps Sample Rate l 2.3 3.5 mA Nap Mode SLP Bit = 0, Conversion Done l 225 400 μA Sleep Mode SLP Bit = 1, Conversion Done l 7 15 μA PD Power Dissipation 14ksps Sample Rate l 11.5 17.5 mW Nap Mode SLP Bit = 0, Conversion Done l 1.125 2 mW Sleep Mode SLP Bit = 1, Conversion Done l 35 75 μW
I2C TIMING CHARACTERISTICS The
l
denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. (Note 4) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
fSCL SCL Clock Frequency l 400 kHz tHD(SDA) Hold Time (Repeated) START Condition l 0.6 μs tLOW LOW Period of the SCL Pin l 1.3 μs tHIGH HIGH Period of the SCL Pin l 0.6 μs tSU(STA) Set-Up Time for a Repeated START l 0.6 μs Condition tHD(DAT) Data Hold Time l 0 0.9 μs tSU(DAT) Data Set-Up Time l 100 ns tr Rise Time for SDA/SCL Signals (Note 11) l 20 + 0.1CB 300 ns tf Fall Time for SDA/SCL Signals (Note 11) l 20 + 0.1CB 300 ns tSU(STO) Set-Up Time for STOP Condition l 0.6 μs tBUF Bus Free Time Between a Second START l 1.3 μs Condition
ADC TIMING CHARACTERISTICS The
l
denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. (Note 4) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
fSMPL Throughput Rate (Successive Reads) l 14 ksps tCONV Conversion Time l 1.3 1.6 μs tACQ Acquisition Time (Note 8) l 240 ns tREFWAKE REFCOMP Wakeup Time (Note 12) CREFCOMP = 10μF, CREF = 2.2μF 200 ms 23015fb 5