Реле Tianbo - ресурс 10 млн переключений

Datasheet ADUM4190-EP (Analog Devices) - 7

ПроизводительAnalog Devices
ОписаниеHigh Stability Isolated Error Amplifier
Страниц / Страница14 / 7 — Enhanced Product. ADuM4190-EP. ABSOLUTE MAXIMUM RATINGS. Table 8. Maximum …
Формат / Размер файлаPDF / 483 Кб
Язык документаанглийский

Enhanced Product. ADuM4190-EP. ABSOLUTE MAXIMUM RATINGS. Table 8. Maximum Continuous Working Voltage1. Table 7. Parameter Max. Unit

Enhanced Product ADuM4190-EP ABSOLUTE MAXIMUM RATINGS Table 8 Maximum Continuous Working Voltage1 Table 7 Parameter Max Unit

45 предложений от 16 поставщиков
Микросхема Буферный усилитель, ANALOG DEVICES ADUM4190BRIZ-RL Isolation Amplifier, High Stability Error, 1 Amplifier, 5kV, 3V to 20V, SOIC, 16Pins
727GS
Весь мир
ADUM4190BRIZ-RL
Analog Devices
от 23 ₽
Lixinc Electronics
Весь мир
ADUM4190BRIZ-RL
Analog Devices
от 152 ₽
Augswan
Весь мир
ADUM4190BRIZ
Analog Devices
по запросу
Кремний
Россия и страны СНГ
ADUM4190BRIZ
Analog Devices
по запросу
Новое семейство LED-драйверов XLC компании MEAN WELL с дополнительными возможностями диммирования

Модельный ряд для этого даташита

Текстовая версия документа

Enhanced Product ADuM4190-EP ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 8. Maximum Continuous Working Voltage1 Table 7. Parameter Max Unit Constraint Parameter Rating
AC Voltage 50-year minimum lifetime Storage Temperature (TST) Range −65°C to +150°C Bipolar Waveform 560 V peak Ambient Operating Temperature −55°C to +125°C (T Unipolar Waveform 1131 V peak A) Range Junction Temperature Range −55°C to +150°C DC Voltage 1131 V peak 50-year minimum lifetime Supply Voltage Range1 VDD1, VDD2 −0.5 V to +24 V 1 Refers to the continuous voltage magnitude imposed across the isolation barrier. VREG1, VREG2 −0.5 V to +3.6 V Input Voltage Range (+IN, −IN) −0.5 V to +3.6 V
ESD CAUTION
Output Voltage Range REFOUT, REFOUT1, COMP, EAOUT −0.5 V to +3.6 V EAOUT2 −0.5 V to +5.5 V Output Current per Output Pin Range −11 mA to +11 mA Common-Mode Transients Range2 −100 kV/μs to +100 kV/μs 1 All voltages are relative to their respective grounds. 2 Refers to common-mode transients across the insulation barrier. Common- mode transients exceeding the absolute maximum ratings may cause latch-up or permanent damage. Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability. Rev. 0 | Page 7 of 14 Document Outline FEATURES ENHANCED FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS PACKAGE CHARACTERISTICS REGULATORY INFORMATION INSULATION AND SAFETY RELATED SPECIFICATIONS RECOMMENDED OPERATING CONDITIONS DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 INSULATION CHARACTERISTICS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS OUTLINE DIMENSIONS ORDERING GUIDE
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка