Data Sheet. ADuM3190. ABSOLUTE MAXIMUM RATINGS. Table 7. Parameter. Rating. Table 8. Maximum Continuous Working Voltage1. Max. Unit

Data Sheet ADuM3190 ABSOLUTE MAXIMUM RATINGS Table 7 Parameter Rating Table 8 Maximum Continuous Working Voltage1 Max Unit

29 предложений от 14 поставщиков
Микросхема Буферный усилитель, OptoCoupler 1CH 3.3V/5V/9V/12V/15V/18V 16Pin QSOP T/R
ЧипСити
Россия
ADUM3190ARQZ-RL7
Analog Devices
110 ₽
Эиком
Россия
ADUM3190ARQZ-RL7
Analog Devices
от 373 ₽
ADUM3190ARQZ-RL7
Analog Devices
от 392 ₽
Maybo
Весь мир
ADUM3190ARQZ-RL7
Analog Devices
825 ₽
Инновационные элементы питания GP: зарядись энергией в КОМПЭЛ!

Модельный ряд для этого даташита

Текстовая версия документа

link to page 18
Data Sheet ADuM3190 ABSOLUTE MAXIMUM RATINGS
T Stresses at or above those listed under Absolute Maximum A = 25°C, unless otherwise noted. Ratings may cause permanent damage to the product. This is a
Table 7.
stress rating only; functional operation of the product at these
Parameter Rating
or any other conditions above those indicated in the operational Storage Temperature (TST) Range −65°C to +150°C section of this specification is not implied. Operation beyond Ambient Operating Temperature −40°C to +125°C the maximum operating conditions for extended periods may (TA) Range affect product reliability. Junction Temperature −40°C to +150°C Supply Voltages
Table 8. Maximum Continuous Working Voltage1
V 1
Parameter Max Unit Constraint
DD1, VDD2 −0.5 V to +24 V V 1 WAVEFORM REG1, VREG2 −0.5 V to +3.6 V Input Voltages (+IN, −IN) −0.5 V to +3.6 V AC Voltage Output Voltages Bipolar 565 V peak 50-year minimum lifetime REF Unipolar 1131 V peak 50-year minimum lifetime OUT, COMP, REFOUT1, EAOUT −0.5 V to +3.6 V EA DC Voltage 1131 V peak 50-year minimum lifetime OUT2 −0.5 V to +5.5 V Output Current per Output Pin −11 mA to +11 mA 1 Refers to continuous voltage magnitude imposed across the isolation Common-Mode Transients2 −100 kV/µs to +100 kV/µs barrier. See the Insulation Lifetime section for more details. 1 All voltages are relative to their respective grounds.
ESD CAUTION
2 Refers to common-mode transients across the insulation barrier. Common- mode transients exceeding the absolute maximum ratings may cause latch-up or permanent damage. Rev. A | Page 7 of 18 Document Outline Features Applications General Description Functional Block Diagram Table of Contents Revision History Specifications Package Characteristics Regulatory Information Insulation and Safety Related Specifications Recommended Operating Conditions DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Test Circuits Applications Information Theory of Operation Accuracy Circuit Operation Isolated Amplifier Circuit Operation Application Block Diagram Setting the Output Voltage DOSA Module Application DC Correctness and Magnetic Field Immunity Insulation Lifetime Packaging and Ordering Information Outline Dimensions Ordering Guide Automotive Products