Аналоги реле Phoenix Contact, Finder, Omron, ABB, Schneider

Datasheet AD640 (Analog Devices) - 10

ПроизводительAnalog Devices
ОписаниеDC-Coupled Demodulating 120 MHz Logarithmic Amplifier
Страниц / Страница12 / 10 — STANDARD. 5962-90955. MICROCIRCUIT DRAWING
Формат / Размер файлаPDF / 82 Кб
Язык документаанглийский

STANDARD. 5962-90955. MICROCIRCUIT DRAWING

STANDARD 5962-90955 MICROCIRCUIT DRAWING

13 предложений от 13 поставщиков
Керамический ЧИП-конденсатор 0603 X7R 0.68мкФ ±10% 50В -55°С…+125°С
Элитан
Россия
CRCW12062R21FKEA
Vishay
2.31 ₽
Контест
Россия
С2-33Н-0.25-931К 1%
2.40 ₽
LifeElectronics
Россия
AD640EB
Analog Devices
по запросу
ТаймЧипс
Россия
AD640BPZ
Analog Devices
по запросу
Какими будут станции зарядки электромобилей в 2030 году: лучшие решения и мировой опыт для отечественных разработок

Модельный ряд для этого даташита

Текстовая версия документа

TABLE II. Electrical test requirements. Test requirements Subgroups Subgroups (in accordance with (in accordance with MIL-STD-883, MIL-PRF-38535, table III) method 5005, table I) Device Device Device class M class Q class V Interim electrical 1 1 1 parameters (see 4.2) Final electrical 1,2,3,4 1/ 1,2,3,4 1/ 1,2,3,4 1/ parameters (see 4.2) Group A test 1,2,3,4 1,2,3,4 1,2,3,4 requirements (see 4.4) Group C end-point electrical 1 1 1 parameters (see 4.4) Group D end-point electrical 1 1 1 parameters (see 4.4) Group E end-point electrical --- --- --- parameters (see 4.4) 1/ PDA applies to subgroup 1. 4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table II herein. 4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883: a. Test condition B or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. b. TA = +125C, minimum. c. Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. 4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. 4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table II herein.
STANDARD
SIZE
5962-90955 MICROCIRCUIT DRAWING A
DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 D 10 DSCC FORM 2234 APR 97