AC-DC и DC-DC преобразователи напряжения Top Power на складе ЭЛТЕХ

Datasheet ADXL345 (Analog Devices) - 6

ПроизводительAnalog Devices
Описание3-Axis, ±2 g/±4 g/±8 g/±16 g Digital Accelerometer
Страниц / Страница41 / 6 — Parameter. Test Conditions. Min. Typ1. Max. Unit
ВерсияE
Формат / Размер файлаPDF / 909 Кб
Язык документаанглийский

Parameter. Test Conditions. Min. Typ1. Max. Unit

Parameter Test Conditions Min Typ1 Max Unit

42 предложений от 19 поставщиков
Датчики Ускорения, ANALOG DEVICES ADXL345TCCZ-EP MEMS Accelerometer, 3-Axis, Digital, X, Y, Z, ± 2g, ± 4g, ± 8g, ± 16g, 2V,...
AiPCBA
Весь мир
ADXL345TCCZ-EP-RL
Analog Devices
742 ₽
ADXL345TCCZ-EP
Analog Devices
от 2 620 ₽
LifeElectronics
Россия
ADXL345TCCZ-EP-RL
Analog Devices
по запросу
ТаймЧипс
Россия
ADXL345TCCZ-EP
Analog Devices
по запросу
Новое семейство LED-драйверов XLC компании MEAN WELL с дополнительными возможностями диммирования

Модельный ряд для этого даташита

Текстовая версия документа

Data Sheet ADXL345
Parameter Test Conditions Min Typ1 Max Unit
TEMPERATURE Operating Temperature Range −40 +85 °C WEIGHT Device Weight 30 mg 1 The typical specifications shown are for at least 68% of the population of parts and are based on the worst case of mean ±1 σ, except for 0 g output and sensitivity, which represents the target value. For 0 g offset and sensitivity, the deviation from the ideal describes the worst case of mean ±1 σ. 2 Cross-axis sensitivity is defined as coupling between any two axes. 3 Bandwidth is the −3 dB frequency and is half the output data rate, bandwidth = ODR/2. 4 The output format for the 3200 Hz and 1600 Hz ODRs is different than the output format for the remaining ODRs. This difference is described in the Data Formatting of Upper Data Rates section. 5 Output data rates below 6.25 Hz exhibit additional offset shift with increased temperature, depending on selected output data rate. Refer to the Offset Performance at Lowest Data Rates section for details. 6 Self-test change is defined as the output (g) when the SELF_TEST bit = 1 (in the DATA_FORMAT register, Address 0x31) minus the output (g) when the SELF_TEST bit = 0. Due to device filtering, the output reaches its final value after 4 × τ when enabling or disabling self-test, where τ = 1/(data rate). The part must be in normal power operation (LOW_POWER bit = 0 in the BW_RATE register, Address 0x2C) for self-test to operate correctly. 7 Turn-on and wake-up times are determined by the user-defined bandwidth. At a 100 Hz data rate, the turn-on and wake-up times are each approximately 11.1 ms. For other data rates, the turn-on and wake-up times are each approximately τ + 1.1 in milliseconds, where τ = 1/(data rate). Rev. E | Page 5 of 40
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка