AC-DC и DC-DC преобразователи напряжения Top Power на складе ЭЛТЕХ

Datasheet ADIS16203 (Analog Devices) - 7

ПроизводительAnalog Devices
ОписаниеProgrammable 360° Inclinometer
Страниц / Страница29 / 7 — ADIS16203. ABSOLUTE MAXIMUM RATINGS Table 3. Parameter Rating. Table 4. …
ВерсияC
Формат / Размер файлаPDF / 459 Кб
Язык документаанглийский

ADIS16203. ABSOLUTE MAXIMUM RATINGS Table 3. Parameter Rating. Table 4. Package Characteristics. Package Type. θJA. θJC Device

ADIS16203 ABSOLUTE MAXIMUM RATINGS Table 3 Parameter Rating Table 4 Package Characteristics Package Type θJA θJC Device

44 предложений от 17 поставщиков
Датчики Ускорения, ANALOG DEVICES ADIS16203CCCZ MEMS Accelerometer, Programmable, Digital, Programmable, 3V, 3.6V, LGA
ADIS16203CCCZ
Analog Devices
от 4 432 ₽
ADIS16203CCCZ
Analog Devices
от 11 538 ₽
Эиком
Россия
ADIS16203CCCZ
Analog Devices
от 12 531 ₽
Кремний
Россия и страны СНГ
ADIS16203CCCZ
Analog Devices
по запросу
ХРОНИКИ РОСТА: причины увеличения доли китайских полупроводниковых компонентов

Модельный ряд для этого даташита

Текстовая версия документа

ADIS16203 ABSOLUTE MAXIMUM RATINGS Table 3.
Stresses above those listed under Absolute Maximum Ratings
Parameter Rating
may cause permanent damage to the device. This is a stress Acceleration (Any Axis, Unpowered) 3500 g rating only; functional operation of the device at these or any Acceleration (Any Axis, Powered) 3500 g other conditions above those indicated in the operational VDD to COM −0.3 V to +7.0 V section of this specification is not implied. Exposure to absolute Digital Input/Output Voltage to COM −0.3 V to +5.5 V maximum rating conditions for extended periods may affect Analog Inputs to COM −0.3 V to VDD + 0.3 V device reliability. Operating Temperature Range −40°C to +125°C
Table 4. Package Characteristics
Storage Temperature Range −65°C to +150°C
Package Type θJA θJC Device Weight
16-Lead LGA 250°C/W 25°C/W 0.6 g
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality. Rev. A | Page 6 of 28 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS TIMING SPECIFICATIONS TIMING DIAGRAMS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMACE CHARACTERISTICS THEORY OF OPERATION OUTPUT RESPONSE TEMPERATURE SENSOR BASIC OPERATION SERIAL PERIPHERAL INTERFACE (SPI) DATA OUTPUT REGISTER ACCESS PROGRAMMING AND CONTROL CONTROL REGISTER OVERVIEW CONTROL REGISTER ACCESS CONTROL REGISTER DETAILS CALIBRATION CALIBRATION REGISTER DEFINITION INCL_NULL Register Definition ALARMS ALM_MAG1 Register Definition ALM_SMPL1 Register Definition ALM_MAG2 Register Definition ALM_SMPL2 Register Definition ALM_CTRL Register Definition SAMPLE PERIOD CONTROL SMPL_TIME Register Definition FILTERING CONTROL AVG_CNT Register Definition POWER-DOWN CONTROL SLP_CNT Register Definition STATUS FEEDBACK STATUS Register Definition COMMAND CONTROL COMMAND Register Definition MISCELLANEOUS CONTROL REGISTER MSC_CTRL Register Definition PERIPHERALS AUXILIARY ADC FUNCTION AUXILIARY DAC FUNCTION AUX_DAC Register Definition GENERAL-PURPOSE I/O CONTROL GPIO_CTRL Register Definition APPLICATIONS HARDWARE CONSIDERATIONS GROUNDING AND BOARD LAYOUT RECOMMENDATIONS SELF-TEST TIPS BAND GAP REFERENCE POWER-ON RESET OPERATION SECOND-LEVEL ASSEMBLY EXAMPLE PAD LAYOUT OUTLINE DIMENSIONS ORDERING GUIDE
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка