STANDARD. 5962-93258. MICROCIRCUIT DRAWING

STANDARD 5962-93258 MICROCIRCUIT DRAWING

5 предложений от 5 поставщиков
Quad Precision, High Speed Operational Amplifier
Кремний
Россия и страны СНГ
OP467GBC
Analog Devices
по запросу
OP467GBC
Analog Devices
по запросу
Maybo
Весь мир
OP467GBC
Analog Devices
по запросу
Augswan
Весь мир
OP467GBC
Analog Devices
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

TABLE I. Electrical performance characteristics - Continued Conditions 1/ 2/ Test Symbol -55C  TA  +125C Group A Device Limits 3/ Unit unless otherwise specified subgroups type Min Max Supply current ICC VCC = 5 V, VOUT = 0 V 1 01 10 mA 2, 3 12 VCC = 15 V, VOUT = 0 V 1 10 2, 3 13 M,D,P,L,R 1 11 Power supply rejection ratio PSRR VCC = 4.5 V to 5.5 V 4/ 1 01 92 dB 2, 3 83 VCC = 4.5 V to 18 V 4/ 1 96 2, 3 86 VCC = 15 V, 4/ Input offset voltage drift TCVIO 8 01 5 V/C TA = +125C, -55C VCC = 5 V, AV = +1, 4/ Gain bandwidth product GBWP 7 01 16 MHz CL = 30 pF, TA = +25C VCC = 15 V, AV = +1, 4/ 21 CL = 30 pF, TA = +25C VCC = 5 V, 4/ Slew rate SR 7 01 85 V/s VIN = 5 V step, AV = +1, RL = 2 k, CL = 30 pF, TA = +25C VCC = 15 V, AV = +1, 4/ 125 VIN = 10 V step, RL = 2 k, CL = 30 pF, TA = +25C VCC = 15 V, AV = +1, 4/ Settling time tS 9 01 300 ns VIN = 10 V step to 0.01% of the final value, TA = +25C 1/ RHA devices supplied to this drawing will meet all levels M, D, P, L, R of irradiation. However, this device is only tested at the ‘R’ level. Pre and Post irradiation values are identical unless otherwise specified in table I. When performing post irradiation electrical measurements for any RHA level, TA = +25C. 2/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. Radiation end point limits for the noted parameters are guaranteed only for the conditions specified in MIL-STD-883, method 1019, condition A. 3/ The limiting terms “min” (minimum) and “max” (maximum) shall be considered to apply to magnitudes only. Negative current shall be defined as conventional current flow out of a device terminal. 4/ This parameter is not tested post-irradiation.
STANDARD
SIZE
5962-93258 MICROCIRCUIT DRAWING A
DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 J 6 DSCC FORM 2234 APR 97