Клеммные колодки Keen Side

Datasheet OP490 (Analog Devices) - 8

ПроизводительAnalog Devices
ОписаниеLow Voltage Micropower Quad Operational Amplifier
Страниц / Страница10 / 8 — STANDARD. 5962-89670. MICROCIRCUIT DRAWING
Формат / Размер файлаPDF / 61 Кб
Язык документаанглийский

STANDARD. 5962-89670. MICROCIRCUIT DRAWING

STANDARD 5962-89670 MICROCIRCUIT DRAWING

46 предложений от 22 поставщиков
Микросхема Операционный усилитель, ANALOG DEVICES OP490GPZ Operational Amplifier, Quad, 4 Amplifier, 20kHz, 0.012V/µs, ± 0.8V to ± 18V, DIP, 14Pins
T-electron
Россия и страны СНГ
OP490GPZ
Analog Devices
654 ₽
Maybo
Весь мир
OP490GPZ
Analog Devices
1 189 ₽
Элитан
Россия
OP490GPZ
Analog Devices
1 715 ₽
OP490GPZ
Analog Devices
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

TABLE II. Electrical test requirements. MIL-STD-883 test requirements Subgroups (in accordance with MIL-STD-883, method 5005, table I) Interim electrical parameters 1 (method 5004) Final electrical test parameters 1*2,3,4,5,6,7 (method 5004) Group A test requirements 1,2,3,4,5,6,7,8** (method 5005) Groups C and D end-point 1 electrical parameters (method 5005) * PDA applies to subgroup 1. ** Subgroups 8, if not tested, shall be guaranteed to the limits specified in table I herein. 4.3.1 Group A inspection. a. Tests shall be as specified in table II herein. b. Subgroups 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted. 4.3.2 Groups C and D inspections. a. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test conditions, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. (2) TA = +125°C, minimum. (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A. 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor- prepared specification or drawing. 6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
STANDARD
SIZE
A 5962-89670 MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 B
8
DSCC FORM 2234 APR 97
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка