Поставки продукции Nuvoton по официальным каналам

Datasheet LT6000, LT6001, LT6002 (Analog Devices) - 7

ПроизводительAnalog Devices
ОписаниеSingle, Dual and Quad, 1.8V, 13µA Precision Rail-to-Rail Op Amps
Страниц / Страница20 / 7 — TYPICAL PERFOR A CE CHARACTERISTICS. TC V. Supply Current vs Supply …
Формат / Размер файлаPDF / 325 Кб
Язык документаанглийский

TYPICAL PERFOR A CE CHARACTERISTICS. TC V. Supply Current vs Supply Voltage. OS Distribution. Change in Input Offset Voltage

TYPICAL PERFOR A CE CHARACTERISTICS TC V Supply Current vs Supply Voltage OS Distribution Change in Input Offset Voltage

28 предложений от 18 поставщиков
LINEAR TECHNOLOGY LT6002IGN#PBF Operational Amplifier, Quad, 4 Amplifier, 60kHz, 0.018V/µs, 1.8V to 16V, SSOP, 16Pins
727GS
Весь мир
LT6002IGN#PBF
Linear Technology
от 144 ₽
AiPCBA
Весь мир
LT6002IGN#TRPBF
Linear Technology
208 ₽
Кремний
Россия и страны СНГ
LT6002IGN PBF
Linear Technology
по запросу
ЗУМ-СМД
Россия
LT6002IGN#TRPBF
Linear Technology
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

LT6000/LT6001/LT6002
W U TYPICAL PERFOR A CE CHARACTERISTICS V TC V Supply Current vs Supply Voltage OS Distribution OS Distribution
30 20 35 VS = 5V, 0V VS = 5V, 0V VCM = 0.5V VCM = 2.5V 18 VCM = 2.5V µA) 30 25 MS8 PACKAGE MS8, GN16, 16 TA = 125°C DD10 PACKAGES 14 –40°C TO 85°C 25 20 12 20 15 T 10 A = 25°C 15 8 10 6 10 PERCENT OF UNITS (%) PERCENT OF UNITS (%) 4 TA = –55°C 5 5 2 SUPPLY CURRENT PER AMPLIFIER ( 0 0 0 –600 –400 –200 0 200 400 600 –5 –4 –3 –2 –1 0 1 2 3 4 5 0 2 4 6 8 10 12 14 16 18 INPUT OFFSET VOLTAGE (µV) DISTRIBUTION (µV/°C) TOTAL SUPPLY VOLTAGE (V) 60012 G01 20012 G02 600012 G03
Change in Input Offset Voltage Input Offset Voltage Input Offset Voltage vs Total Supply Voltage vs Total Supply Voltage vs Input Common Mode Voltage
300 400 400 V V CM = 0.5V CM = 0.5V VS = 5V, 0V TYPICAL PART TYPICAL PART 250 300 300 µV) 200 µV) 200 TA = 125°C µV) 200 150 100 TA = 125°C TA = 25°C 100 T 100 A = 25°C T 0 T A = 125°C A = 25°C 50 0 OFFSET VOLTAGE ( –100 OFFSET VOLTAGE ( 0 T TA = –55°C A = –55°C –100 CHANGE IN OFFSET VOLTAGE ( –100 TA = –55°C –50 –100 –300 –200 1 1.5 2 2.5 3 0 2 4 6 8 10 12 14 16 18 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 TOTAL SUPPLY VOLTAGE (V) TOTAL SUPPLY VOLTAGE (V) INPUT COMMON MODE VOLTAGE (V) 60012 G35 600012 G05 60012 G06
Input Bias Current Output Saturation Voltage Output Saturation Voltage vs Common Mode Voltage vs Load Current (Output High) vs Load Current (Output Low)
12.5 1.0 1.0 VS = 5V, 0V VS = 5V, 0V VS = 5V, 0V INPUT OVERDRIVE = 30mV INPUT OVERDRIVE = 30mV 10.0 7.5 T T T A = 25°C A = 25°C A = 125°C 5.0 TA = 125°C TA = 125°C 0.1 0.1 2.5 TA = –55°C TA = –55°C TA = 25°C 0 TA = –55°C INPUT BIAS CURRENT (nA) –2.5 OUTPUT HIGH SATURATION VOLTAGE (V) OUTPUT LOW SATURATION VOLTAGE (V) –5.0 0.01 0.01 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0.001 0.01 0.1 1 10 0.001 0.01 0.1 1 10 COMMON MODE VOLTAGE (V) SOURCING LOAD CURRENT (mA) SINKING LOAD CURRENT (mA) 60012 G07 60012 G08 60012 G08 600012fa 7