AC-DC и DC-DC преобразователи напряжения Top Power на складе ЭЛТЕХ

Datasheet ACS71020 (Allegro) - 3

ПроизводительAllegro
ОписаниеSingle Phase, Isolated, Power Monitoring IC with Voltage Zero Crossing and Overcurrent Detection
Страниц / Страница37 / 3 — Single Phase, Isolated, Power Monitoring IC. ACS71020 with Voltage Zero …
Формат / Размер файлаPDF / 1.0 Мб
Язык документаанглийский

Single Phase, Isolated, Power Monitoring IC. ACS71020 with Voltage Zero Crossing and Overcurrent Detection

Single Phase, Isolated, Power Monitoring IC ACS71020 with Voltage Zero Crossing and Overcurrent Detection

25 предложений от 9 поставщиков
, Current Sensor Current Sensor AC/DC Current 5V 16-Pin SOIC W T/R
AllElco Electronics
Весь мир
ACS71020KMABTR-015B5-SPI
Allegro
от 104 ₽
AiPCBA
Весь мир
ACS71020KMABTR-015B5-SPI
Allegro
219 ₽
Зенер
Россия и страны ТС
ACS71020KMABTR-015B5-SPI
от 364 ₽
Maybo
Весь мир
ACS71020KMABTR-015B5-SPI
Allegro
589 ₽

Модельный ряд для этого даташита

Текстовая версия документа

Single Phase, Isolated, Power Monitoring IC ACS71020 with Voltage Zero Crossing and Overcurrent Detection ABSOLUTE MAXIMUM RATINGS Characteristic Symbol Notes Rating Units
Supply Voltage VCC 6.5 V Reverse Supply Voltage VRCC –0.5 V Input Voltage VINP, VINN VCC + 0.5 V Reverse Input Voltage VRNP, VRNN –0.5 V Digital I/O Voltage VDIO 6 V SPI, I2C, and general purpose I/O Reverse Digital I/O Voltage VRDIO –0.5 V Operating Ambient Temperature TA Range K –40 to 125 °C Junction Temperature TJ(max) 165 °C Storage Temperature Tstg –65 to 170 °C
ISOLATION CHARACTERISTICS Characteristic Symbol Notes Rating Unit
Agency type-tested for 60 seconds per UL 60950-1 Dielectric Strength Test Voltage VISO (edition 2). Production tested at 3000 VRMS for 1 second, in 4800 VRMS accordance with UL 60950-1 (edition 2). (certification pending) 1480 VPK Working Voltage for Basic Isolation V Maximum approved working voltage for basic (single) isolation WVBI according to UL 60950-1 (edition 2). (certification pending) 1047 VRMS or VDC 730 VPK Working Voltage for Reinforced Isolation V Maximum approved working voltage for reinforced isolation WVRI according to UL 60950-1 (edition 2). (certification pending) 517 VRMS or VDC Clearance Dcl Minimum distance through air from IP leads to signal leads. 7.5 mm Creepage D Minimum distance along package body from IP leads to signal cr leads 7.5 mm
THERMAL CHARACTERISTICS
See https://www.allegromicro.com/en/Design-Center/Technical-Documents/Hall-Effect-Sensor-IC-Publications/DC-and-Transient-Cur- rent-Capability-Fuse-Characteristics.aspx. Allegro MicroSystems, LLC 3 955 Perimeter Road Manchester, NH 03103-3353 U.S.A. www.allegromicro.com Document Outline Features and Benefits Description Package Typical Application Selection Guide Absolute Maximum Ratings Isolation Characteristics Thermal Characteristics Functional Block Diagram Pinout Diagram and Terminal List Digital I/O Electrical Characteristics Data Acquisition ADCs Raw Signal Sensitivity and Offset Trim Phase Compensation Zero Crossing Power Calculations Digital Communication Registers and EEPROM EEPROM Error Checking and Correction (ECC) Memory Map Volatile Memory Map Application Connections Recommended PCB Layout Package Outline Drawing