Поставки продукции Megawin по официальным каналам - микроконтроллеры, мосты USB-UART

Datasheet MA12040 (Infineon) - 7

ПроизводительInfineon
Описание2x40W ultra power efficient, fully Integrated audio amplifier IC with analog input
Страниц / Страница86 / 7 — 5 Absolute Maximum Ratings. Table 5-1. Parameter. Value. Unit. Power …
Версия01_00
Формат / Размер файлаPDF / 1.7 Мб
Язык документаанглийский

5 Absolute Maximum Ratings. Table 5-1. Parameter. Value. Unit. Power Supplies. Input / Output. Thermal Conditions

5 Absolute Maximum Ratings Table 5-1 Parameter Value Unit Power Supplies Input / Output Thermal Conditions

27 предложений от 13 поставщиков
Усилитель звуковой мощности, 20 Вт, D, 2 канала, 4В до 18В, QFN-EP, 64 вывод(-ов)
Lixinc Electronics
Весь мир
MA12040XUMA1
Infineon
от 223 ₽
Эиком
Россия
MA12040XUMA1
Infineon
516 ₽
Зенер
Россия и страны ТС
MA12040XUMA1
594 ₽
Элитан
Россия
MA12040XUMA1
Infineon
603 ₽
ХРОНИКИ РОСТА: причины увеличения доли китайских полупроводниковых компонентов

Модельный ряд для этого даташита

Текстовая версия документа

5 Absolute Maximum Ratings Table 5-1 Parameter Value Unit Power Supplies
Power stage supply voltage, PVDD -0.5 to +20 V System supply voltage, DVDD, AVDD -0.5 to +6.0 V
Input / Output
Analog: IN0A, IN0B, IN1A, IN1B -0.5 to +6.0 V Logic: /ENABLE, /MUTE, /ERROR, /CLIP, MSEL0, MSEL1 -0.5 to +6.0 V Clock: CLKIO, CLKM/S -0.5 to +6.0 V Interface: SCL, SDA, AD0, AD1 -0.5 to +6.0 V Output current, Logic and Interface 25 mA
Thermal Conditions
Ambient temperature range, TA -40 to +85 °C Junction temperature range, TJ -40 to +150 °C Storage temperature range -65 to +150 °C Thermal resistance, Junction-to-Ambient 23 °C/W Thermal resistance, Junction-to-EPAD 2.3 °C/W Lead soldering temperature, 10s +300 °C
Electrostatic Discharge (ESD)
Human body model (HBM) ± 2000 V Charged device model (CDM) ± 1000 V
PLEASE NOTE:
Device usage beyond the above stated ratings may cause permanent damage to the device. Permanent usage at the above stated ratings may limit device lifetime and result in reduced reliability. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. See “Recommended Operation Conditions” for continuous functional ratings. Datasheet Please read the Important Notice and Warnings at the end of this document V 1.0