Контрактное производство и проектные поставки для российских производителей электроники

Datasheet AP3917D (Diodes) - 3

ПроизводительDiodes
ОписаниеUniversal AC High Voltage Step Down Power Switcher
Страниц / Страница12 / 3 — AP3917D. Absolute Maximum Ratings. Symbol. Parameter. Rating. Unit. U D. …
Формат / Размер файлаPDF / 587 Кб
Язык документаанглийский

AP3917D. Absolute Maximum Ratings. Symbol. Parameter. Rating. Unit. U D. Recommended Operating Conditions. Min. Max. www.diodes.com

AP3917D Absolute Maximum Ratings Symbol Parameter Rating Unit U D Recommended Operating Conditions Min Max www.diodes.com

36 предложений от 12 поставщиков
IC: PMIC; ШИМ-контроллер; 300мА; Ch: 1; SO7; buck,flyback; 8,2÷8,8В
ChipWorker
Весь мир
AP3917DS7-13
Diodes
22 ₽
AiPCBA
Весь мир
AP3917DS7-13
Diodes
45 ₽
AP3917DS7-13
Diodes
от 47 ₽
Maybo
Весь мир
AP3917DS7-13
Diodes
55 ₽
Компактные и мощные DC/DC-преобразователи MEAN WELL серии RQB со склада КОМПЭЛ

Модельный ряд для этого даташита

Текстовая версия документа

AP3917D Absolute Maximum Ratings
(Note 4)
Symbol Parameter Rating Unit
VDSS Drain Pin Voltage -0.7 to 700 V VBP Internally Generated Control Circuit Power Supply 8.9 V VFB, VS FB Pin Voltage and S Pin Voltage -0.7 to 5.5 V PD Continuous Power Dissipation (TA = +25°C) 1 W TJ Operating Junction Temperature +125 °C
T
TSTG Storage Temperature -65 to +150 °C
C
TLEAD Lead Temperature (Soldering, 10s) +300 °C
U D
θJA Thermal Resistance (Junction to Ambient) (Note 5) 91 °C/W
O
— ESD (Human Body Model) 4000 V
R
— ESD (Charge Device Model) 1000 V
P W
Note: 4. Stresses greater than those listed under Absolute Maximum Ratings can cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied.
E
Exposure to Absolute Maximum Ratings for extended periods can affect device reliability.
N
5. Test condition: Device mounted on FR-4 substrate PC board, 2oz copper, with 1inch2 cooling area.
Recommended Operating Conditions Symbol Parameter Min Max Unit
VBP Supply Voltage 8.2 8.8 V VDSS Drain-Source Voltage (Note 6) — 560 V TA Ambient Temperature -40 +125 °C Note: 6. The drain-source voltage is 80% of VDS in the aging condition. AP3917D 3 of 12 June 2019 Document number: DS41540 Rev. 4 - 2