Absolute Maximum Ratings. Electrical Characteristics. PARAMETER. SYMBOL. CONDITIONS. MIN. TYP. MAX. UNITS. SERIAL INTERFACE

Absolute Maximum Ratings Electrical Characteristics PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS SERIAL INTERFACE

Какими будут станции зарядки электромобилей в 2030 году: лучшие решения и мировой опыт для отечественных разработок

Модельный ряд для этого даташита

Текстовая версия документа

MAX6675 Cold-Junction-Compensated K-Thermocouple- to-Digital Converter (0°C to +1024°C)
Absolute Maximum Ratings
Supply Voltage (VCC to GND) ... -0.3V to +6V Storage Temperature Range ... -65°C to +150°C SO, SCK, CS, T-, T+ to GND ...-0.3V to VCC + 0.3V Junction Temperature .. +150°C SO Current ... 50mA SO Package ESD Protection (Human Body Model) .. ±2000V Vapor Phase (60s) . ...+215°C Continuous Power Dissipation (TA = +70°C) Infrared (15s) ..+220°C 8-Pin SO (derate 5.88mW/°C above +70°C) ... 471mW Lead Temperature (soldering, 10s) ... +300°C Operating Temperature Range .. -20°C to +85°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Electrical Characteristics
(VCC = +3.0V to +5.5V, TA = -20°C to +85°C, unless otherwise noted. Typical values specified at +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
TTHERMOCOUPLE = +700°C, VCC = +3.3V -5 +5 TA = +25°C (Note 2) VCC = +5V -6 +6 T V Temperature Error THERMOCOUPLE = 0°C to CC = +3.3V -8 +8 LSB +700°C, TA = +25°C (Note 2) VCC = +5V -9 +9 TTHERMOCOUPLE = +700°C VCC = +3.3V -17 +17 to +1000°C, TA = +25°C (Note 2) VCC = +5V -19 +19 Thermocouple Conversion 10.25 µV/LSB Constant Cold-Junction T V A = - 2 0 ° C t o CC = +3.3V -3.0 +3.0 °C Compensation Error +85°C (Note 2) VCC = +5V -3.0 +3.0 Resolution 0.25 °C Thermocouple Input 60 kW Impedance Supply Voltage VCC 3.0 5.5 V Supply Current ICC 0.7 1.5 mA Power-On Reset Threshold VCC rising 1 2 2.5 V Power-On Reset Hysteresis 50 mV Conversion Time (Note 2) 0.17 0.22 s
SERIAL INTERFACE
Input Low Voltage V 0.3 x IL V V CC Input High Voltage V 0.7 x IH V V CC Input Leakage Current ILEAK VIN = GND or VCC ±5 µA Input Capacitance CIN 5 pF www.maximintegrated.com Maxim Integrated │