Поставки продукции Megawin по официальным каналам - микроконтроллеры, мосты USB-UART

Datasheet MAX30102 (Maxim) - 30

ПроизводительMaxim
ОписаниеHigh-Sensitivity Pulse Oximeter and Heart-Rate Sensor for Wearable Health
Страниц / Страница32 / 30 — Read Data Format
Формат / Размер файлаPDF / 917 Кб
Язык документаанглийский

Read Data Format

Read Data Format

5 предложений от 5 поставщиков
MAXIM INTEGRATED PRODUCTS MAX30105EFD+ Smoke Detector Sensor, Digital, OESIP, 14 Pins, 1.7 V, 2 VNew
ChipWorker
Весь мир
MAX30105EFD+T
Maxim
339 ₽
ЧипСити
Россия
MAX30105EFD+T
Maxim
365 ₽
AiPCBA
Весь мир
MAX30105EFD+T
Maxim
426 ₽
Maybo
Весь мир
MAX30105EFD+
Maxim
по запросу
Энергия без перебоев: источники питания MEAN WELL на DIN-рейку

Модельный ряд для этого даташита

Текстовая версия документа

link to page 30 MAX30102 High-Sensitivity Pulse Oximeter and Heart-Rate Sensor for Wearable Health
Read Data Format
read the next register after FIFO_DATA, an I2C write For the read operation, two I2C operations must be command is necessary to change the location of the read performed. First, the slave ID byte is sent followed by pointer. the I2C register that you wish to read. Then a REPEAT Figure 10 and Figure 11 show the process of reading one START (Sr) condition is sent, followed by the read slave byte and multiple bytes of data. ID. The MAX30102 then begins sending data beginning An initial write operation is required to send the read with the register selected in the first operation. The read register address. pointer increments automatically, so the device continues sending data from additional registers in sequential order Data is sent from registers in sequential order, starting until a STOP (P) condition is received. The exception to from the register selected in the initial I2C write operation. this is the FIFO_DATA register, at which the read pointer If the FIFO_DATA register is read, the read pointer will not no longer increments when reading additional bytes. To automatically increment, and subsequent bytes of data will contain the contents of the FIFO. S 1 0 1 0 1 1 1 R/W = 0 ACK A7 A6 A5 A4 A3 A2 A1 A0 ACK SLAVE ID REGISTER ADDRESS Sr 1 0 1 0 1 1 1 R/W ACK D7 D6 D5 D4 D3 D2 D1 D0 NACK P = 1 SLAVE ID DATA BYTE S = START CONDITION ACK = ACKNOWLEDGE BY THE RECEIVER Sr = REPEATED START CONDITION NACK = NOT ACKNOWLEDGE P = STOP CONDITION Figure 10. Reading One Byte of Data from MAX30102 S 1 0 1 0 1 1 1 R/W = 0 ACK A7 A6 A5 A4 A3 A2 A1 A0 ACK SLAVE ID REGISTER ADDRESS Sr 1 0 1 0 1 1 1 R/W ACK D7 D6 D5 D4 D3 D2 D1 D0 AM = 1 SLAVE ID DATA 1 D7 D6 D5 D4 D3 D2 D1 D0 AM D7 D6 D5 D4 D3 D2 D1 D0 NACK P DATA n-1 DATA n S = START CONDITION ACK = ACKNOWLEDGE BY THE RECEIVER Sr = REPEATED START CONDITION AM = ACKNOWLEDGE BY THE MASTER P = STOP CONDITION NACK = NOT ACKNOWLEDGE Figure 11. Reading Multiple Bytes of Data from the MAX30102 www.maximintegrated.com Maxim Integrated │ 30
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка