OKW: приборные корпуса из Германии

Datasheet ADuM6010 (Analog Devices) - 8

ПроизводительAnalog Devices
ОписаниеIntegrated DC-to-DC Converter
Страниц / Страница16 / 8 — ADuM6010. Data Sheet. ABSOLUTE MAXIMUM RATINGS. Table 13. Parameter. …
ВерсияB
Формат / Размер файлаPDF / 438 Кб
Язык документаанглийский

ADuM6010. Data Sheet. ABSOLUTE MAXIMUM RATINGS. Table 13. Parameter. Rating. Table 14. Maximum Continuous Working Voltage

ADuM6010 Data Sheet ABSOLUTE MAXIMUM RATINGS Table 13 Parameter Rating Table 14 Maximum Continuous Working Voltage

30 предложений от 16 поставщиков
Преобразователь DC/DC, Conv DC-DC Step Down 3.3V 5V 20Pin SSOP T/R
Lixinc Electronics
Весь мир
ADUM6010ARSZ-RL7
Analog Devices
от 304 ₽
ИМЭК
Россия и страны ТС
ADUM6010ARSZ
Analog Devices
573 ₽
ЭИК
Россия
ADUM6010ARSZ
Analog Devices
от 867 ₽
Augswan
Весь мир
ADUM6010ARSZ-RL7
Analog Devices
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

link to page 13
ADuM6010 Data Sheet ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted. Stresses at or above those listed under Absolute Maximum
Table 13.
Ratings may cause permanent damage to the product. This is a
Parameter Rating
stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational Storage Temperature (TST) −55°C to +150°C section of this specification is not implied. Operation beyond Ambient Operating Temperature (TA) −40°C to +105°C the maximum operating conditions for extended periods may Supply Voltages (VDDP, VISO)1 −0.5 V to +7.0 V affect product reliability. VISO Supply Current2 TA = −40°C to +105°C 30 mA
Table 14. Maximum Continuous Working Voltage
Input Voltage (PDIS, VSEL)1, 3 −0.5 V to VDD + 0.5 V
Supporting 50-Year Minimum Lifetime1
Common-Mode Transients4 −100 kV/µs to +100 kV/µs
Applicable Parameter Max Unit Certification
1 All voltages are relative to their respective ground. 2 The V AC Voltage ISO provides current for dc and dynamic loads on the VISO I/O channels. This current must be included when determining the total Bipolar Waveform 560 V peak All certifications, VISO supply current. 50-year operation 3 VDD can be either VDDP or VISO depending on the whether the input is on Unipolar Waveform 560 V peak the primary or secondary side of the part respectively. 4 Refers to common-mode transients across the insulation barrier. DC Voltage Common-mode transients exceeding the absolute maximum ratings may |DC Peak Voltage| 560 V peak cause latch-up or permanent damage. 1 Refers to the continuous voltage magnitude imposed across the isola- tion barrier. See the Insulation Lifetime section for more information.
ESD CAUTION
Rev. B | Page 8 of 16 Document Outline Features Applications General Description Functional Block Diagram Revision History Specifications Electrical Characteristics—5 V Primary Input Supply/5 V Secondary Isolated Supply Electrical Characteristics—3.3 V Primary Input Supply/3.3 V Secondary Isolated Supply Electrical Characteristics—5 V Primary Input Supply/3.3 V Secondary Isolated Supply Package Characteristics Regulatory Approvals Insulation and Safety-Related Specifications DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Truth Table Typical Performance Characteristics Applications Information PCB Layout Thermal Analysis EMI Considerations Insulation Lifetime Outline Dimensions Ordering Guide