AC-DC и DC-DC преобразователи напряжения Top Power на складе ЭЛТЕХ

Datasheet MAX1682, MAX1683 (Maxim) - 2

ПроизводительMaxim
ОписаниеSwitched-Capacitor Voltage Doublers
Страниц / Страница9 / 2 — Switched-Capacitor Voltage Doublers. ABSOLUTE MAXIMUM RATINGS. Note 1:. …
Формат / Размер файлаPDF / 181 Кб
Язык документаанглийский

Switched-Capacitor Voltage Doublers. ABSOLUTE MAXIMUM RATINGS. Note 1:. ELECTRICAL CHARACTERISTICS. PARAMETER. CONDITIONS. MIN. TYP

Switched-Capacitor Voltage Doublers ABSOLUTE MAXIMUM RATINGS Note 1: ELECTRICAL CHARACTERISTICS PARAMETER CONDITIONS MIN TYP

39 предложений от 19 поставщиков
Удвоитель DC/DC преобразователя напряжения с подкачкой заряда, 2В до 5.5В вход, 45мА выход, SOT-23-5
AllElco Electronics
Весь мир
MAX1683EUK+T
Maxim
от 28 ₽
ЭИК
Россия
MAX1683EUK+T
Analog Devices
от 295 ₽
AiPCBA
Весь мир
MAX1683EUK+T
Maxim
439 ₽
Augswan
Весь мир
MAX1683EUK-T
Analog Devices
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

Switched-Capacitor Voltage Doublers ABSOLUTE MAXIMUM RATINGS
IN to GND ...+6V to -0.3V Operating Temperature Range OUT to GND ...+12V, VIN - 0.3V MAX1682EUK/MAX1683EUK ...-40°C to +85°C OUT Output Current..50mA Junction Temperature ..+150°C Output Short-Circuit Duration ...1sec (Note 1) Storage Temperature Range ...-65°C to +160°C Continuous Power Dissipation (TA = +70°C) Lead Temperature (soldering, 10sec) ...+300°C SOT23-5 (derate 7.1mW/°C above +70°C)...571mW Soldering Temperature (reflow) ...+260°C
Note 1:
Avoid shorting OUT to GND, as it may damage the device. For temperatures above +85°C, shorting OUT to GND even instantaneously will damage the device. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VIN = +5.0V, capacitor values from Table 2, TA = 0°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.)
PARAMETER CONDITIONS MIN TYP MAX UNITS MAX1682/MAX1683
MAX1682 110 145 No-Load Supply Current TA = +25°C µA MAX1683 230 310 TA = +25°C 2.0 1.7 5.5 Supply Voltage Range RLOAD = 10kΩ V TA = 0°C to +85°C 2.1 1.8 5.5 Minimum Operating Voltage (Note 2) 1 V MAX1682 8.4 12 15.6 Oscillator Frequency TA = +25°C kHz MAX1683 24.5 35 45.5 TA = +25°C 20 50 Output Resistance IOUT = 5mA Ω TA = 0°C to +85°C 65 Voltage Conversion Efficiency IOUT = 0mA, TA = +25°C 98 99.9 %
Note 2:
Once started, the MAX1682/MAX1683 typically operate down to 1V.
ELECTRICAL CHARACTERISTICS
(VIN = +5.0V, capacitor values from Table 2, TA = -40°C to +85°C, unless otherwise noted.) (Note 3)
PARAMETER CONDITIONS MIN TYP MAX UNITS
MAX1682 160 No-Load Supply Current µA MAX1683 350 Supply Voltage Range RLOAD = 10kΩ 2.3 5.5 V MAX1682 6.6 18.6 Oscillator Frequency kHz MAX1683 17.5 57.8 Output Resistance IOUT = 5mA 65 Ω Voltage Conversion Efficiency IOUT = 0mA 97 %
Note 3:
Specifications at -40°C to +85°C are guaranteed by design.
2 _______________________________________________________________________________________
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка