На склад поступили жидко-кристаллические индикаторы и дисплеи от KSE

Catalog CR Magnetics Transducers, Relays, Transformers, Indicators (CR Magnetics) - 9

ПроизводительCR Magnetics
ОписаниеSelection Guide
Страниц / Страница38 / 9 — 2-Wire Current Transmitter,. 4-20 mA Output. CR4320. Features. …
Формат / Размер файлаPDF / 1.6 Мб
Язык документаанглийский

2-Wire Current Transmitter,. 4-20 mA Output. CR4320. Features. Specifications. Part Numbers. Accuracy:. 4-20 MA CURRENT TRANSMITTER

2-Wire Current Transmitter, 4-20 mA Output CR4320 Features Specifications Part Numbers Accuracy: 4-20 MA CURRENT TRANSMITTER

Критерии выбора литиевых аккумуляторов и батареек: что необходимо учитывать разработчикам

Модельный ряд для этого даташита

Текстовая версия документа

2-Wire Current Transmitter, 4-20 mA Output
The
CR4320
series, loop-powered, 2-Wire Current Transmitter produces a calibrated 4-20 mA. DC output current directly proportional to the average RMS value of the input alternating current. The controlled current output is unaffected by variations in supply voltage, interconnect and load impedance (within specification limits) to provide a highly accu- rate means for monitoring alternating current over long distances.
Features
• Permanently calibrated • Loop-powered
®
• Fully isolated • 12 different ranges E154235 • 2 case styles, .93” (23.6 mm) and 1.25” (31.8 mm) Case Style 2 • window opening • Output overload protected Case Style 1
Specifications Part Numbers Accuracy:
±0.5% Full-Scale (FS)
CR4320
- ❑ ❑ ❑
4-20 MA CURRENT TRANSMITTER Repeatability:
Less than 0.1%
Ripple & Noise:
Full-Scale (FS) Case 1% Max., peak to peak Range in AC Amps Style
Calibrated Signal Out: 5
0-5 1 4-20 mA DC
Response Time: 10
0-10 1 200 ms max., 10-90% FS
15
0-15 1
Max. Signal Out: 20
0-20 1 30 mA DC
30
0-30 1
Temperature Coefficient:
± 0.04%/°C
50
0-50 1
Supply Voltage: 75
0-75 1 24 Vdc ±10%
100
0-100 1
Frequency:
50/60 Hz
150
0-150 1
Continuous Thermal Current Rating Factor: 200
0-200 1 1.33 @ 30°C
300
0-300 2
Short Time Thermal Current 400
0-400 2
Rating Factor (For 30 Seconds):
6.0 x Full Scale for AC ranges up to 200 Amp. 4.0 x Full Scale for ranges 300 and 400 Amp.
Output Load:
0 to 600 ohms
Insulation Class: Internet Resources http://www.crmagnetics.com/
600 V, BIL 10 kV Full Wave
Reverse Polarity Protection:
• Transducer Selection Guide: transducer.html Yes • Application Sheet: pdf/ancr4320-1.pdf
Operating Temperature Range:
• Pricing: pricing/4320.html -30°C to +60°C • Motor Loads: mot_ld_a.pdf
Storage Temperature Range:
-55°C to +85°C
Approximate Weight:
1.5 pounds (.68 kg) 8
Электронные компоненты. Бесплатная доставка по России