Муфты электромонтажные от производителя Fucon

Datasheet 74AHCU04 (Nexperia) - 5

ПроизводительNexperia
ОписаниеHex unbuffered inverter
Страниц / Страница14 / 5 — Nexperia. 74AHCU04. Hex unbuffered inverter. 10. Dynamic characteristics …
Версия18052020
Формат / Размер файлаPDF / 247 Кб
Язык документаанглийский

Nexperia. 74AHCU04. Hex unbuffered inverter. 10. Dynamic characteristics Table 7. Dynamic characteristics. Symbol Parameter

Nexperia 74AHCU04 Hex unbuffered inverter 10 Dynamic characteristics Table 7 Dynamic characteristics Symbol Parameter

Выбираем схему BMS для заряда литий-железофосфатных (LiFePO4) аккумуляторов

Модельный ряд для этого даташита

Текстовая версия документа

link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 5
Nexperia 74AHCU04 Hex unbuffered inverter 10. Dynamic characteristics Table 7. Dynamic characteristics
GND = 0 V; For test circuit see Fig. 7.
Symbol Parameter Conditions 25 °C -40 °C to -40 °C to Unit +85 °C +125 °C Min Typ Max Min Max Min Max
tpd propagation nA to nY; see Fig. 6 [1] delay VCC = 3.0 V to 3.6 V; CL = 15 pF [2] - 3.0 7.1 1.0 8.5 1.0 9.0 ns VCC = 3.0 V to 3.6 V; CL = 50 pF [2] - 3.4 10.6 1.0 12.0 1.0 13.5 ns VCC = 4.5 V to 5.5 V; CL = 15 pF [3] - 2.4 5.5 1.0 6.5 1.0 7.0 ns VCC = 4.5 V to 5.5 V; CL = 50 pF [3] - 3.5 7.0 1.0 8.0 1.0 9.0 ns CPD power CL = 50 pF; fi = 1 MHz; [4] - 9.1 - - - - - pF dissipation VI = GND to VCC capacitance [1] tpd is the same as tPLH and tPHL. [2] Typical values are measured at VCC = 3.3 V. [3] Typical values are measured at VCC = 5.0 V. [4] CPD is used to determine the dynamic power dissipation (PD in μW). P 2 2 D = CPD × VCC × fi × N + Σ(CL × VCC × fo) where: fi = input frequency in MHz; fo = output frequency in MHz; CL = output load capacitance in pF; VCC = supply voltage in V; N = number of inputs switching; Σ(C 2 L × VCC × fo) = sum of outputs.
10.1. Waveforms
VCC V V I VO I PULSE DUT GENERATOR nA input VM VM CL RT 50 pF GND tPHL tPLH mna034 VOH Test data is given in Table 7. Definitions for test circuit: nY output VM VM CL = Load capacitance including jig and probe VOL mna344 capacitance. VM = 0.5 × VCC; VI = GND to VCC. RT = Termination resistance should be equal to
Fig. 6. The input (nA) to output (nY) propagation delay
output impedance Zo of the pulse generator.
times Fig. 7. Test circuit for measuring switching times
74AHCU04 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2020. Al rights reserved
Product data sheet Rev. 5 — 18 May 2020 5 / 14
Document Outline 1. General description 2. Features and benefits 3. Ordering information 4. Functional diagram 5. Pinning information 5.1. Pinning 5.2. Pin description 6. Functional description 7. Limiting values 8. Recommended operating conditions 9. Static characteristics 10. Dynamic characteristics 10.1. Waveforms 11. Typical transfer characteristics 12. Application information 13. Package outline 14. Abbreviations 15. Revision history 16. Legal information Contents
Электронные компоненты. Бесплатная доставка по России