AC-DC и DC-DC преобразователи напряжения Top Power на складе ЭЛТЕХ

Datasheet MAX4271, MAX4272, MAX4273 (Maxim) - 4

ПроизводительMaxim
Описание3V to 12V Current-Limiting Hot-Swap Controllers with Autoretry, DualSpeed/BiLevel Fault Protection
Страниц / Страница26 / 4 — 3V to 12V Current-Limiting Hot-Swap Controllers with Autoretry, …
Формат / Размер файлаPDF / 419 Кб
Язык документаанглийский

3V to 12V Current-Limiting Hot-Swap Controllers with Autoretry, DualSpeed/BiLevel Fault Protection

3V to 12V Current-Limiting Hot-Swap Controllers with Autoretry, DualSpeed/BiLevel Fault Protection

22 предложений от 18 поставщиков
Контролер нагрузки, Hot Swap Controller 1CH 13.2V N-Channel Positive Low Voltage 16Pin QSOP T/R
727GS
Весь мир
MAX4273EEE+
Maxim
от 228 ₽
Lixinc Electronics
Весь мир
MAX4273EEE+T
Maxim
от 277 ₽
Элитан
Россия
MAX4273EEE+
Analog Devices
1 103 ₽
Augswan
Весь мир
MAX4273EEE
Analog Devices
по запросу
ХРОНИКИ РОСТА: причины увеличения доли китайских полупроводниковых компонентов

Модельный ряд для этого даташита

Текстовая версия документа

3V to 12V Current-Limiting Hot-Swap Controllers with Autoretry, DualSpeed/BiLevel Fault Protection ELECTRICAL CHARACTERISTICS (continued)
(VIN = +2.7V to +13.2V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = +5V and TA = +25°C.) (Note 3)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input can be driven to the absolute Input Voltage Range maximum limit without false output -0.1 13.2 V inversion Input Bias Current IB,COMP 0.001 1 μA To unlatch a fault MAX4271, MAX4273 with ON Pulse Width Low (Note 7) tRESTART 20 μs CTIM = IN
DIGITAL OUTPUTS
(STAT, OUTC) Output Leakage Current VSTAT ≤ 13.2, VOUTC ≤ 13.2 1 μA Output Voltage Low VOL ISINK = 1mA 0.4 V
RETRY TIMING
(MAX4272, MAX4273) Retry Timeout Period tRETRY 100nF capacitor on CTIM (Note 5) 0.5 1 2 s Default Retry tRETRY CTIM = no connection 176 µs Timeout Period (default)
UNDERVOLTAGE LOCKOUT
(UVLO) Startup is initiated when this threshold is Threshold VUVLO 2.25 2.67 V exceeded at IN Hysteresis V U V LO,H YS T 100 mV Time the input voltage must exceed Delay tD,UVLO undervoltage lockout before startup is 100 150 200 ms
MAX4271/MAX4272/MAX4273
initiated
Note 3:
All devices are 100% tested at TA = +25°C. All temperature limits are guaranteed by design.
Note 4:
Startup period is the time during which the slow comparator is ignored and the fast comparator regulates the sense current. It is measured from the time ON is brought high.
Note 5:
Inferred from test with CTON = 10nF (MAX4273) and CTIM = 1nF.
Note 6:
The current available at GATE is a function of VGATE (see Typical Operating Characteristics).
Note 7:
Guaranteed by design.
4 _______________________________________________________________________________________
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка