Клеммные колодки Keen Side

Datasheet SGP40 (Sensirion) - 6

ПроизводительSensirion
ОписаниеIndoor Air Quality Sensor for VOC Measurements
Страниц / Страница19 / 6 — Condition. Parameter. Min. Max. Unit. Table 4. Figure 3. Figure 4. 2.4 …
Формат / Размер файлаPDF / 957 Кб
Язык документаанглийский

Condition. Parameter. Min. Max. Unit. Table 4. Figure 3. Figure 4. 2.4 Absolute Minimum and Maximum Ratings. Table 5

Condition Parameter Min Max Unit Table 4 Figure 3 Figure 4 2.4 Absolute Minimum and Maximum Ratings Table 5

43 предложений от 13 поставщиков
Биполярные транзисторы с изолированным затвором (IGBT) Dis High Perf IGBT
AllElco Electronics
Весь мир
SGP40-D-R4
Sensirion
от 115 ₽
ChipWorker
Весь мир
SGP40-D-R4
375 ₽
Триема
Россия
SGP40-D-R4 Датчик SSR
Sensirion
415 ₽
AiPCBA
Весь мир
SGP40-D-R4
577 ₽
Решения для систем охлаждения

Модельный ряд для этого даташита

Текстовая версия документа

link to page 7
Condition Parameter Min. Max. Unit
Operating conditions Relative humidity 0 90 % RH Temperature −10 50 °C Operating conditions of Humidity 1.5 (−13) 30 (+31) g m−3 (°C dew point) humidity compensation or – 90 % RH (the smaller) Temperature −10 50 °C Storage conditions Relative humidity 0 80 % RH Temperature 5 30 °C
Table 4
Recommended humidity and temperature conditions for storing and operating the SGP40. Dew point refers to maximum humidity allowed at minimum and maximum temperature, respectively.
Figure 3
Recommended relative humidity and temperature for
Figure 4
Recommended relative humidity and temperature for operating the SGP40. Green area marks conditions for which storing the SGP40. humidity compensation has been optimized. Additionally, gray areas mark operating conditions without considering the humidity compensation feature. To ensure an optimal performance of the SGP40, Handling and Assembly Instructions for SGPxx Gas Sensors as well as the Design-in Guide for Integrating SGP4x Gas Sensors need to be followed.
2.4 Absolute Minimum and Maximum Ratings
Stress levels beyond those listed in
Table 5
may cause permanent damage to the device. Exposure to minimum/maximum rating conditions for extended periods may affect sensor performance and reliability of the device. www.sensirion.com Version 1.1 – September 2021 6/19
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка