ADGS1208/. ADGS1209. Data Sheet. CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx. Table 3. ADGS1208, One Channel On Parameter. 25°C. 85°C

ADGS1208/ ADGS1209 Data Sheet CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx Table 3 ADGS1208, One Channel On Parameter 25°C 85°C

21 предложений от 11 поставщиков
, Analog Multiplexer Dual 4:1 24-Pin LFCSP EP T/R
IC Home
Весь мир
ADGS1209BCPZ-RL7
Analog Devices
628 ₽
Зенер
Россия и страны ТС
ADGS1209BCPZ
от 649 ₽
Maybo
Весь мир
ADGS1209BCPZ
Analog Devices
1 515 ₽
Augswan
Весь мир
ADGS1209BCPZ
Analog Devices
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

ADGS1208/ ADGS1209 Data Sheet CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx Table 3. ADGS1208, One Channel On Parameter 25°C 85°C 125°C Unit
CONTINUOUS CURRENT, Sx OR D1 VDD = +15 V, VSS = −15 V (θJA = 63.1°C/W) 29.3 21.9 14.1 mA max VDD = 12 V, VSS = 0 V (θJA = 63.1°C/W) 37.7 27.3 19 mA max 1 Sx refers to the S1 to S8 pins.
Table 4. ADGS1209, Two Channels On Parameter 25°C 85°C 125°C Unit
CONTINUOUS CURRENT, Sx OR Dx1 VDD = +15 V, VSS = −15 V (θJA = 63.1°C/W) 21.8 16.1 9.9 mA max VDD = 12 V, VSS = 0 V (θJA = 63.1°C/W) 28.2 21.2 13.4 mA max 1 Sx refers to the S1A to S4A and S1B to S4B pins, and Dx refers to the DA and DB pins. Rev. 0 | Page 8 of 33 Document Outline Features Applications General Description Functional Block Diagrams Product Highlights Revision History Specifications ±15 V Dual Supply 12 V Single Supply Continuous Current per Channel, Sx or Dx Timing Characteristics Timing Diagrams Absolute Maximum Ratings Thermal Resistance ESD Caution Pin Configurations and Function Descriptions Typical Performance Characteristics Test Circuits Terminology Theory of Operation Address Mode Error Detection Features Cyclic Redundancy Check (CRC) Error Detection SCLK Count Error Detection Invalid Read/Write Address Error Detection Clearing the Error Flags Register Burst Mode Software Reset Daisy-Chain Mode Power-On Reset Round Robin Mode General-Purpose Outputs Applications Information Digital Input Buffers Settling Time Power Supply Rails Power Supply Recommendations Register Summaries Register Details Switch Data Register Error Configuration Register Error Flags Register Burst Enable Register Round Robin Enable Register Round Robin Channel Configuration Register CNV Edge Select Register Software Reset Register Outline Dimensions Ordering Guide