ADG436 ABSOLUTE MAXIMUM RATINGS
TA = 25°C unless otherwise noted.
Table 3.
Stresses above those listed under Absolute Maximum Ratings
Parameter Rating
may cause permanent damage to the device. This is a stress VDD to VSS +44 V rating only; functional operation of the device at these or any V other conditions above those listed in the operational sections DD to GND −0.3 V to +30 V V of this specification is not implied. Exposure to absolute SS to GND +0.3 V to −30 V Analog, Digital Inputs1 V maximum rating conditions for extended periods may affect SS − 2 V to VDD + 2V or 20 mA, whichever occurs first device reliability. Only one absolute maximum rating may be Continuous Current, S or D 20 mA applied at any one time. Peak Current, S or D (pulsed at 40 mA 1 ms, 10% Duty Cycle max)
Table 4. Truth Table
Operating Temperature Range
Logic Switch A Switch B
Industrial (B Version) −40°C to +85°C 0 Off On Storage Temperature Range −65°C to +125°C 1 On Off Junction Temperature 150°C θJA, Thermal Impedance PDIP Package 117°C/W SOIC Package 77°C/W Lead Temperature, Soldering 260°C (10 sec) Lead Temperature, Soldering Vapor Phase (60 sec) 215°C Infrared (15 sec) 220°C 1 Overvoltages at IN, S, or D are clamped by internal diodes. Current should be limited to the maximum ratings given.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degrada- tion or loss of functionality. Rev. B | Page 5 of 12 Document Outline FEATURES APPLICATIONS FUNCTIONAL BLOCK DIAGRAM GENERAL DESCRIPTION PRODUCT HIGHLIGHTS SPECIFICATIONS DUAL SUPPLY SINGLE SUPPLY ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TERMINOLOGY TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS APPLICATIONS INFORMATION ADG436 SUPPLY VOLTAGES POWER-SUPPLY SEQUENCING OUTLINE DIMENSIONS ORDERING GUIDE