Pin-Selectable Watchdog Timers. MAX6369–MAX6374. ELECTRICAL CHARACTERISTICS (continued). PARAMETER. SYMBOL. CONDITIONS. MIN. TYP. MAX

35 предложений от 19 поставщиков Схема контроля, 2.5В до 5.5В питание, 0.8В порог, 10мс задержка, активный низкий, открытый сток |
| MAX6373KA-T Analog Devices | от 218 ₽ | |
| MAX6373KA+T Maxim | от 740 ₽ | |
| MAX6373KA+T Analog Devices | по запросу | |
| MAX6373KAT Maxim | по запросу | |
Модельный ряд для этого даташита
Текстовая версия документа
Pin-Selectable Watchdog Timers MAX6369–MAX6374 ELECTRICAL CHARACTERISTICS (continued)
(VCC = +2.5V to +5.5V, SET_ = VCC or GND, TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C and VCC = +3V.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SET2 = 0, SET1 = 0, SET0 = 0 1 3 SET2 = 0, SET1 = 0, SET0 = VCC 10 30 ms SET2 = 0, SET1 = VCC, SET0 = 0 30 90 Watchdog Timeout SET2 = 0, SET1 = VCC, SET0 = VCC Watchdog Disabled t Period WD SET2 = VCC, SET1 = 0, SET0 = 0 100 300 ms SET2 = VCC, SET1 = 0, SET0 = VCC 1 3 SET2 = VCC, SET1 = VCC, SET0 = 0 10 30 s SET2 = VCC, SET1 = VCC, SET0 = VCC 60 180
MAX6371/MAX6372
SET2 = 0, SET1 = VCC, SET0 = VCC Watchdog Disabled Startup Delay Period tDELAY All other SET_ conditions 60 180 s SET2 = 0, SET1 = 0, SET0 = 0 1 3 SET2 = 0, SET1 = 0, SET0 = VCC 3 9 ms SET2 = 0, SET1 = VCC, SET0 = 0 10 30 Watchdog Time-Out SET2 = 0, SET1 = VCC, SET0 = VCC Watchdog Disabled tWD Period SET2 = VCC, SET1 = 0, SET0 = 0 100 300 ms SET2 = VCC, SET1 = 0, SET0 = VCC 300 900 SET2 = VCC, SET1 = VCC, SET0 = 0 3 9 s SET2 = VCC, SET1 = VCC, SET0 = VCC 60 180
MAX6373/MAX6374
SET2 = 0, SET1 = 0, SET0 = 0 3 9 ms SET2 = 0, SET1 = 0, SET0 = VCC 3 9 s SET2 = 0, SET1 = VCC, SET0 = 0 60 180 SET2 = 0, SET1 = VCC, SET0 = VCC Watchdog Disabled Startup Delay Period tDELAY SET2 = VCC, SET1 = 0, SET0 = 0 200 600 µs SET2 = VCC, SET1 = 0, SET0 = VCC First Edge (Note 3) SET2 = VCC, SET1 = VCC, SET0 = 0 First Edge (Note 3) SET2 = VCC, SET1 = VCC, SET0 = VCC 60 180 s SET2 = 0, SET1 = 0, SET0 = 0 3 9 ms SET2 = 0, SET1 = 0, SET0 = VCC 3 9 s SET2 = 0, SET1 = VCC, SET0 = 0 1 3 Watchdog Timeout SET2 = 0, SET1 = VCC, SET0 = VCC Watchdog Disabled tWD Period SET2 = VCC, SET1 = 0, SET0 = 0 30 90 µs SET2 = VCC, SET1 = 0, SET0 = VCC 1 3 SET2 = VCC, SET1 = VCC, SET0 = 0 10 30 s SET2 = VCC, SET1 = VCC, SET0 = VCC 10 30
_______________________________________________________________________________________ 3