Клеммы, реле, разъемы Degson со склада в России

Datasheet MAX6701, MAX6701A, MAX6702, MAX6702A, MAX6703, MAX6703A, MAX6704, MAX6705, MAX6705A, MAX6706, MAX6706A, MAX6707, MAX6707A, MAX6708 (Analog Devices) - 2

ПроизводительAnalog Devices
ОписаниеLow-Voltage, SOT23, µP Supervisors with Power-Fail In/Out, Manual Reset, and Watchdog Timer
Страниц / Страница12 / 2 — Absolute Maximum Ratings. Electrical Characteristics. PARAMETER. SYMBOL. …
Формат / Размер файлаPDF / 1.2 Мб
Язык документаанглийский

Absolute Maximum Ratings. Electrical Characteristics. PARAMETER. SYMBOL. CONDITIONS. MIN. TYP. MAX. UNITS

Absolute Maximum Ratings Electrical Characteristics PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS

31 предложений от 24 поставщиков
Контрольный чип источника питания, Low-Voltage, SOT23, µP Supervisors with Power-Fail In/Out, Manual Reset, and Watchdog Timer
AllElco Electronics
Весь мир
MAX6707TKA
Maxim
40 ₽
LifeElectronics
Россия
MAX6707ALKA-T
Maxim
по запросу
МосЧип
Россия
MAX6707AMKA+T
Maxim
по запросу
MAX6707LKR
Maxim
по запросу
Новое семейство LED-драйверов XLC компании MEAN WELL с дополнительными возможностями диммирования

Модельный ряд для этого даташита

Текстовая версия документа

MAX6701-08/ Low-Voltage, SOT23 µP Supervisors with Power-Fail MAX6701A-03A/ In/Out, Manual Reset, and Watchdog Timer MAX6705A-07A
Absolute Maximum Ratings
VCC ...-0.3V to +6.0V Continuous Power Dissipation (TA = +70°C) Open-Drain RESET, WDO, PFO ..-0.3V to +6.0V 8-Pin SOT23 (derate 8.9mW/°C above +70°C) ..714mW Push-Pull RESET, RESET, WDO, PFO ... -0.3V to (VCC + 0.3V) Operating Temperature Range ... -40°C to +125°C MR, WDI, PFI, RST_IN1, RST_IN2 ... -0.3V to (VCC + 0.3V) Junction Temperature ..+150°C Input Current (VCC) ..20mA Storage Temperature Range .. -65°C to +150°C Output Current (O, WDO) ..20mA Lead Temperature (soldering, 10s) ...+300°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Electrical Characteristics
(VCC = +4.25V to +5.5V for L/M versions, VCC = +2.55V to +3.6V for the T/S/R versions, VCC = +2.1V to +2.75V for the Z/Y versions. TA = -40°C to +125°C, unless otherwise specified. Typical values are at TA = +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
T Operating Voltage Range V A = 0°C to +125°C 1.0 5.5 CC V TA = -40°C to +125°C 1.2 5.5 VCC < 5.5V, no load 12 25 Supply Current MR Unconnected ICC VCC < 3.6V, no load 9 20 µA VCC < 3.6V, no load (MAX6708 only) 6 20 T MAX670_L/MAX670_AL A = -40°C to +85°C 4.50 4.63 4.75 TA = -40°C to +125°C 4.47 4.78 T MAX670_M/MAX670_AM A = -40°C to +85°C 4.25 4.38 4.50 TA = -40°C to +125°C 4.22 4.53 T MAX670_T/MAX670_AT A = -40°C to +85°C 3.00 3.08 3.15 TA = -40°C to +125°C 2.97 3.17 V T CC Reset Threshold A = -40°C to +85°C 2.85 2.93 3.00 (V MAX670_S/MAX670_AS V CC falling) VTH TA = -40°C to +125°C 2.83 3.02 T MAX670_R/MAX670_AR A = -40°C to +85°C 2.55 2.63 2.70 TA = -40°C to +125°C 2.53 2.72 T MAX670_Z/MAX670_AZ A = -40°C to +85°C 2.25 2.32 2.38 TA = -40°C to +125°C 2.24 2.40 T MAX670_Y/MAX670_AY A = -40°C to +85°C 2.12 2.19 2.25 TA = -40°C to +125°C 2.11 2.27 Reset Threshold Temperature Coefficient ∆VTH 60 ppm/°C VCC to Reset Output Delay VCC falling at 10mV/µs 12 µs T Reset Timeout Period t A = -40°C to +85°C 140 200 280 RP ms TA = -40°C to +125°C 120 300 MAX6701(A)/MAX6702(A)/MAX6703(A)/MAX6705(A)/ VCC Falling to WDO Delay 5 µs MAX6706(A)/MAX6707(A) PFI, RST_IN1, RST_IN2 TA = -40°C to +85°C 602 618 634 Threshold VCC = 1.8V to 5.5V mV TA = -40°C to +125°C 593 642 PFI Hysteresis 6 mV www.maximintegrated.com Maxim Integrated │ 2