Реле Tianbo - ресурс 10 млн переключений

Datasheet BCX42 (Infineon) - 7

ПроизводительInfineon
ОписаниеNPN Silicon AF and Switching Transistor
Страниц / Страница7 / 7 — BCX42. Edition 2009-11-16 Published by Infineon Technologies AG 81726 …
Формат / Размер файлаPDF / 539 Кб
Язык документаанглийский

BCX42. Edition 2009-11-16 Published by Infineon Technologies AG 81726 Munich, Germany. 2009 Infineon Technologies AG

BCX42 Edition 2009-11-16 Published by Infineon Technologies AG 81726 Munich, Germany 2009 Infineon Technologies AG

46 предложений от 27 поставщиков
Двухполюсный плоскостной транзистор, SOT-23 PNP 125V 0.8A
Lixinc Electronics
Весь мир
BCX42E6327
Infineon
4.89 ₽
Romstore
Россия, Беларусь
BCX42
от 18 ₽
BCX42E6327
Infineon
от 20 ₽
BCX42E-6874
Infineon
по запросу

Модельный ряд для этого даташита

Текстовая версия документа

BCX42 Edition 2009-11-16 Published by Infineon Technologies AG 81726 Munich, Germany 2009 Infineon Technologies AG All Rights Reserved. Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (<www.infineon.com>).
Warnings
Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. 7 2011-10-04
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка