AC-DC и DC-DC преобразователи напряжения Top Power на складе ЭЛТЕХ

Datasheet VOFD343A (Vishay) - 4

ПроизводительVishay
Описание4 A Output Current IGBT and MOSFET Driver
Страниц / Страница12 / 4 — VOFD343A. TEST CIRCUITS. SWITCHING CHARACTERISTICS. PARAMETER. TEST …
Формат / Размер файлаPDF / 225 Кб
Язык документаанглийский

VOFD343A. TEST CIRCUITS. SWITCHING CHARACTERISTICS. PARAMETER. TEST CONDITION. SYMBOL. MIN. TYP. MAX. UNIT. Note

VOFD343A TEST CIRCUITS SWITCHING CHARACTERISTICS PARAMETER TEST CONDITION SYMBOL MIN TYP MAX UNIT Note

5 предложений от 2 поставщиков
Разное
Элитан
Россия
VOFD343A-X018T
Vishay
145 ₽
VOFD343A-X018T
Vishay
от 173 ₽
Интернет-магазин ДКО Электронщик снова с вами!

Модельный ряд для этого даташита

Текстовая версия документа

VOFD343A
www.vishay.com Vishay Semiconductors
TEST CIRCUITS
1 6 1 6 0.1 µF I = 7 mA 0.1 µF F to 16 mA IF + V = 15 V 2 5 + V CC 2 5 CC V > 5 V to 30 V V > 5 V O O 3 4 3 4 Shield Shield Fig. 1 - IFLH Test Circuit Fig. 2 - UVLO Test Circuit
SWITCHING CHARACTERISTICS
(Tamb = 25 °C, VCC - VEE = 30 V unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Propagation delay time to VO = “low” tPHL 50 - 200 ns Propagation delay time to VO = “high” Rg = 10 Ω, Cg = 15 nF, tPLH 50 - 200 ns f = 20 kHz, duty cycle = 50 %, Pulse width distortion PWD - 10 70 ns IF = 7 mA to 16 mA, Propagation delay difference (1) V PDD -100 - 100 ns CC = 15 V to 30 V, Output rise time (10 % to 90 %) VEE = ground tr - 35 - ns Output fall time (90 % to 10 %) tf - 35 - ns
Note
(1) The difference between tPHL and tPLH between any two parts, series parts, or channels under same test conditions 1 6 I 0.1 µF F + VCC t t V > 5 V r f O IF 2 5 VOH 90 % Rg VO 50 % Cg 10 % 3 4 VOL Shield t t PLH PHL Fig. 3 - tPLH, tPHL, tr and tf Test Circuit and Waveforms
COMMON MODE TRANSIENT IMMUNITY
(Tamb = 25 °C, VCC - VEE = 30 V unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Common mode transient immunity at IF = 10 mA to 16 mA, |CM high level output (V H| 35 50 - kV/μs O = “high”) (1) VCM = 1500 V, VCC = 30 V Common mode transient immunity at VF = 0 V, VCM = 1500 V, |CM low level output (V L| 35 50 - kV/μs O = “low”) (2) VCC = 30 V
Notes
(1) CMH is the maximum rate of rise of the common mode voltage that can be sustained with the output voltage in the logic high state (VO > 15 V) (2) CML is the maximum rate of fall of the common mode voltage that can be sustained with the output voltage in the logic low state (VO < 1 V) Rev. 1.0, 20-Jun-2024
4
Document Number: 80486 For technical questions, contact: optocoupleranswers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка