VIA0050DD. SAFETY AND INSULATION RATINGS PARAMETER. TEST CONDITION. SYMBOL. VALUE. UNIT

VIA0050DD SAFETY AND INSULATION RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT

Новое семейство LED-драйверов XLC компании MEAN WELL с дополнительными возможностями диммирования

Модельный ряд для этого даташита

Текстовая версия документа

VIA0050DD
www.vishay.com Vishay Semiconductors
SAFETY AND INSULATION RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT
Climatic classification According to IEC 68 part 1 40 / 125 / 21 Comparative tracking index DIN EN 60112 (VDE 0303-11); IEC 60112 CTI > 600 V Maximum rated withstanding TEST = VISO, t = 1 min (qualification); V V isolation voltage TEST = 1.2 x VISO, ISO 5000 VRMS t = 1 s (100 % production test) Maximum transient isolation voltage t = 1 min VIOTM 8000 Vpeak Maximum repetitive isolation voltage VIORM 2121 Vpeak Test method per IEC 60065, Maximum surge isolation voltage 1.2/50 μs waveform, VIOSM 6250 Vpeak VTEST = VIOSM x 1.6 AC voltage 1500 VRMS Maximum working isolation voltage VIOWM DC voltage 2121 VDC Tamb = 25 °C, VIO = 500 V RIO > 1012 Ω Isolation resistance Tamb = 125 °C, VIO = 500 V RIO > 1010 Ω Tamb = 150 °C, VIO = 500 V RIO > 109 Ω θ Total power dissipation at 25 °C JA = 86 °C/W, VI = 5.5 V, Tj = 150 °C, P T S 1430 mW amb = 25 °C θ Safety input, output, or supply current JA = 86 °C/W, VI = 5.5 V, Tj = 150 °C, I T S 260 mA amb = 25 °C Maximum safety temperature TS 150 °C Creepage distance ≥ 8 mm SOP-8 (300 mils) Clearance distance ≥ 8 mm Insulation thickness Distance through insulation DTI 32 μm Material group IEC 60664-1 I For rated mains voltage ≤ 150 VRMS I to IV For rated mains voltage ≤ 300 VRMS I to IV For rated mains voltage ≤ 400 VRMS I to IV Pollution degree per DIN VDE 0110, table 1 2 VIORM x 1.875 = Vpd(m), Input to output test voltage, method B1 100 % production test; Vpd(m) 3977 Vpeak tini = tm = 1 s, partial discharge < 5 pC V After environmental tests subgroup 1 IORM x 1.6 = Vpd(m), tini = 1 s, V t pd(m) 3394 Vpeak m = 10 s, partial discharge < 5 pC Isolation capacitance f = 1 MHz CIO 0.8 pF Axis Title 300 10000 250 ) A (m 200 1000 rrent u ne ne ine C 150 ng 1st li iti 2nd li 2nd l m 100 100 Li fety a S 50 0 10 0 50 100 150 200 T - Ambient Temperature (°C) amb Fig. 23 - VIA0050DD Thermal Derating Curve, Dependence of Safety Limiting Values With Case Temperature per DIN VOE V0884-11 Rev. 1.2, 02-Apr-2025
9
Document Number: 80900 For technical questions, contact: optocoupleranswers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
ТМ Электроникс. Электронные компоненты и приборы. Скидки, кэшбэк и бесплатная доставка