MLX75305 Datasheet 8. General Electrical Specifications All voltages are referenced to Vss. Symbol Parameter Conditions Min Typ Max Unit Tes t1 Vdd Supply Voltage 3 5.5 V V Idd Static Power Supply Current At Vdd=5.5V, 2 mA V unloaded output Vdark Dark level (a), (c) Ee=0 Tamb=-40 .. 85˚C 4 160 mV V Tamb=85 .. 125˚C 4 210 mV V Re10 Responsivity Gain 10 (option (a), Vout range = -15% 70 +15% mV/(µW/ V code A) 50mV..4.5V, 25˚C cm2) Re1 Responsivity Gain 1 (option (a), Vout range = -15% 7 +15% mV/(µW/ V code B) 50mV..4.5V, 25˚C cm2) NLAO RMS Non Linearity (a), in the 10..90% +/-2 % V Output Range TC Temperature Coefficient (b), Ee=46µW/cm² -0.16 %/C X For visual light: 0.06 %/C X For NIR (λ=850nm): λ0.3 Spectral Bandwidth Tamb=25˚C 500 1000 nm X Emax Absolute Maximum Irradiance Vdd=5V, λ=850nm, 50*E µW/cm2 X Tamb=25˚C Vout Spd Area of photodiode 0.36 mm2 D VOH Maximum Output voltage high (a), 4.9 4.95 V V Ee=15*EVout...Emax tVdd_rise Vdd rise time 10..90% of Vdd 4 µs V tsetup Electrical setup-time (a), Vout within Vdd/2 70 140 µs V +/- 5% 1 The column Test indicates if the specific parameter is tested in production. Following symbols are used: V: the specific parameter is tested in production X: the specific parameter is verified in characterization, but is not tested in production (e.g. timings and capacitances) D: the specific parameter is guaranteed by design and is not tested as such in production REVISION 9 - OCTOBER 17, 2016 Page 5 of 12 [390107530501]