AC-DC и DC-DC преобразователи напряжения Top Power на складе ЭЛТЕХ

Datasheet RTM3000 oscilloscope (Rohde&Schwarz) - 6

ПроизводительRohde&Schwarz
ОписаниеOscilloscope Specifications
Страниц / Страница32 / 6 — Version 05.01, March 2018. Acquisition system. Trigger system. Rohde …
Версия05.01
Формат / Размер файлаPDF / 2.2 Мб
Язык документаанглийский

Version 05.01, March 2018. Acquisition system. Trigger system. Rohde & Schwarz

Version 05.01, March 2018 Acquisition system Trigger system Rohde & Schwarz

Новое семейство LED-драйверов XLC компании MEAN WELL с дополнительными возможностями диммирования

Текстовая версия документа

Version 05.01, March 2018 Acquisition system
Maximum realtime sampling rate normal mode 2.5 Gsample/s interleaved mode, 5 Gsample/s if following channels are not used simultaneously: channel 1 and channel 2 channel 3 and channel 4 logic channels Memory depth per channel normal mode 40 Msample per channel interleaved mode, 80 Msample per channel if following channels are not used simultaneously: channel 1 and channel 2 channel 3 and channel 4 logic channels Acquisition modes sample first sample in decimation interval peak detect largest and smallest sample in decimation interval high resolution average value of all samples in decimation interval envelope envelope of acquired waveforms average average over a series of acquired waveforms envelope + peak detect envelope of acquired waveforms with active peak detect envelope + high resolution envelope of acquired waveforms with active high resolution average + high resolution average over a series of acquired high resolution waveforms Number of averaged waveforms 2 to 100 000 Waveform acquisition rate dot display, single channel, auto record up to 64 000 waveforms/s length
Trigger system
Trigger level range ±5 div from center of screen Trigger modes auto, normal, single, n single with R&S®RTM-K15 option Hold-off range time inactive or 51.2 ns to 13.7 s Trigger types edge, width, video, pattern, runt, rise time, fall time, serial bus, line, timeout Edge trigger A trigger events rising edge, falling edge, both edges R&S®RTM3002 channel 1, channel 2, logic channels from D15 to D0 (with R&S®RTM-B1 option), external trigger input R&S®RTM3004 channel 1, channel 2, channel 3, channel 4, logic channels from D15 to D0 (with R&S®RTM-B1 option), external trigger input trigger coupling DC, AC (attenuates < 10 Hz (meas.)), LF reject (attenuates < 10 kHz (meas.)) trigger filter HF reject (attenuates > 100 kHz (meas.)), noise reject (attenuates > 100 MHz (meas.)) selectable trigger hysteresis automatic, small, medium, large
6 Rohde & Schwarz
R&S®RTM Oscilloscope